NSN 5925-01-066-6226
Overload Switch
Single pole type body style, plastic case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number 578961 for national stock number 5925010666226.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-066-6226.
-
MPN or Model
578961
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.1 lb -
Body Style
Single pole type -
Body Length
2.510 inches -
Body Width
Between 0.730 inches and 0.780 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.660 inches and 1.960 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.046 inches and 2.078 inches -
Switch Contact Arrangement
Single pole, double throw -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.109 inches and 0.171 inches -
Mounting Surface To Terminal End Distance
2.800 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
2 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
1.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
0.600 at 200 pct single location and 8.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Shock resistant and vibration resistant -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
10.0 ac and 2.0 dc -
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc -
Test Data Document
81349-mil-c-55629 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.). -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 threaded stud -
Specification Data
81349-mil-c-55629/2 government specification
More from these suppliers
- 5950-00-057-4579 MPN 9157529Reactor
- 5930-00-072-8387 MPN 10108589Rotary Switch
- 5905-00-242-2423 MPN 10630283-307Inductive Wire Wound Fixed Resistor
- 5935-00-258-0138 MPN 10105834Electrical Receptacle Connector
- 5905-00-283-3808 MPN 8017963Film Fixed Resistor
- 5930-00-331-0696 MPN 8152915Rotary Switch
- 5935-00-411-5223 MPN 11437060-1Electrical Receptacle Connector
- 5935-00-435-1891 MPN 10177678Electrical Connector Backshell
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-066-6226 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
578961 | Itt Telecom Products Corp |
70-369MG3-1-28 | Eaton Corp |
70-132-57MG6 | Eaton Corp |
AM12HEMG6-1-50VDC4 | Eaton Corp |
AM12HKMG3-1-50VDC4 | Eaton Corp |
AM12HKMG6-1-50VDC4 | Eaton Corp |
CB10D1 | Raytheon Technical Services Company |
M55629/2-015 | Military Specifications |
MIL-PRF-55629/2D | Military Specifications |
9747553-4 | U S Army Aviation And Missile |
711570-164 | Raytheon Company |
MIL-C-55629/2 | Military Specifications |