NSN 5925-01-067-2927
Overload Switch
Single pole type body style, metal case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number 1710C for national stock number 5925010672927.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-067-2927.
-
MPN or Model
1710C
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.5 lb -
Body Style
Single pole type -
Bushing Length
Between 0.220 inches and 0.280 inches -
Body Length
2.189 inches -
Body Width
0.750 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
Between 1.160 inches and 1.220 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 1.796 inches and 1.828 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
2.000 inches -
Pole Quantity
1 -
Arc Quenching Method
Air -
Mounting Facility Type And Quantity
2 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac single location and 10.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
205.0 ac single location and 30.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac single location and 6000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Thermal single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 push-pull -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 at 200 pct single location and 55.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location -
Frequency In Hertz
400.0 single location -
Unpackaged Unit Weight
0.250 pounds -
Test Data Document
81349-mil-c-5809 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.). -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 tab w/screw -
Specification Data
96906-ms25244 government standard
More from these suppliers
- 5935-00-081-1144 MPN BACC45DF14S2PElectrical Plug Connector
- 5935-01-167-8188 MPN M85049/9-05WElectrical Connector Backshell
- 5935-00-023-1295 MPN AS81703Electrical Receptacle Connector
- 5935-00-201-0844 MPN M81511/06EE01S1Electrical Plug Connector
- 5935-00-517-8519 MPN AS50151Electrical Plug Connector
- 5935-00-904-1104 MPN AS50151Electrical Plug Connector
- 5935-01-129-9140 MPN AS50151Electrical Receptacle Connector
- 5935-01-170-5821 MPN AS85049/9Electrical Connector Backshell
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-067-2927 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
1710C | Wood Electric Operations Potter And |
AS25244 | Society Of Automotive Engineers Inc |
AS58091 | Society Of Automotive Engineers Inc |
MS25244-P-10 | Society Of Automotive Engineers Inc |
BACC18J10A | Boeing Company, The |
104-210-102 | Tyco Electronics Corporation |
BACC18J10A | The Boeing Company |
MS25017-10 | Solar Turbines Incorporated |
2010B | Wood Electric Operations Potter And |
1710CB | Wood Electric Operations Potter And |
MIL-C-5809 | Military Specifications |
MS25244-P-10 | Military Standards |
C5809BMS2505-10 | Military Specifications |
BACC18J-10 | The Boeing Company |
MS25244-P10 | Society Of Automotive Engineers Inc |
AS58091 | Sae International |
MS25244-P10 | Sae International |