NSN 5925-01-076-6377
Overload Switch
Multipole-multiple actuator type body style, plastic case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number JA2-A2-A-15-2 for national stock number 5925010766377.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-076-6377.
-
MPN or Model
JA2-A2-A-15-2
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.4 lb -
Body Style
Multipole-multiple actuator type -
Body Length
Between 1.968 inches and 2.032 inches -
Body Width
Between 1.468 inches and 1.532 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.528 inches and 1.592 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.718 inches and 0.782 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 1.628 inches and 1.692 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.718 inches and 0.782 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.098 inches and 0.162 inches -
Mounting Surface To Terminal End Distance
Between 2.233 inches and 2.297 inches -
Pole Quantity
2 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
4 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
2 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One and two linked -
Auxiliary Switch Function And Quantity
2 alarm -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Switch Location And Position Designation
Internal at each pole -
Trip Delay Time In Seconds Per Rated Continuous Current
2.500 at 200 pct all locations and 20.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant and humidity resistant and shock resistant and vibration resistant -
Switch Terminal Type
Quick disconnect, male -
Switch Current Rating And Type In Amps
10.0 ac and 5.0 dc -
Switch Voltage Rating And Type In Volts
250.0 ac and 30.0 dc -
Frequency In Hertz
50.0 all locations or 60.0 all locations -
Unpackaged Unit Weight
5.000 ounces -
Thread Series Designator
Unc -
Terminal Type And Quantity
4 quick disconnect, male
More from these suppliers
- 5925-00-161-9168 MPN AM333MG6-5-15Circuit Breaker
- 5925-00-238-6376 MPN 53-168-2MG3Circuit Breaker
- 5925-00-434-2642 MPN JA2-B3-A-10-2Circuit Breaker
- 5925-00-729-7749 MPN 3X1163MG4-9-416-400-13Circuit Breaker
- 5925-00-845-6612 MPN SM3-1-5AMP28VDCTDC58Circuit Breaker
- 5925-00-882-7306 MPN 2263S50Circuit Breaker
- 5925-00-912-5326 MPN AM333MG6-10-250VAC60C4Circuit Breaker
- 5925-00-922-6008 MPN 78-126-1Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-076-6377 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
JA2-A2-A-15-2 | Eaton Corp |