NSN 5925-01-092-4868
Overload Switch
Multipole-multiple actuator type body style, 0.164 inches mounting slot width, plastic case material, fragility factor: moderately rugged.
Manufacturer part number 260-0006-020 for national stock number 5925010924868.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-092-4868.
-
MPN or Model
260-0006-020
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-multiple actuator type -
Mounting Slot Width
0.164 inches -
Body Length
5.844 inches -
Body Width
3.093 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
3.546 inches -
Center To Center Distance Between Terminals Parallel To Width
1.032 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.032 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.218 inches -
Mounting Surface To Terminal End Distance
2.609 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
6 threaded hole and 6 slot -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
480.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
140.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
6.000 at 200 pct all locations and 25.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Frequency In Hertz
60.0 all locations -
Unpackaged Unit Weight
2.000 pounds -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5940-00-006-5830 MPN 304-0295-00Lug Terminal
- 5950-00-060-8090 MPN 278-1745-000Radio Frequency Coil
- 5930-00-084-8501 MPN 259-1423-00Rotary Switch
- 5950-00-086-8998 MPN 678-0023-00Reactor
- 5905-00-101-9654 MPN 745-3104-000Composition Fixed Resistor
- 5935-00-102-6031 MPN 357-9559-00Electrical Plug Connector
- 5935-00-102-6143 MPN 371-1284-320Electrical Receptacle Connector
- 5940-00-177-9881 MPN 306-0001-00Terminal Board
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-092-4868 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
260-0006-020 | Rockwell Collins, Inc. |
CD3-Z117-2 | Eaton Corp |