NSN 5925-01-099-0693
Overload Switch
Multipole-multiple actuator type body style, plastic case material, moderately rugged fragility factor, pole quantity: 2.
Manufacturer part number W-C-375/14-004 for national stock number 5925010990693.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-099-0693.
-
MPN or Model
W-C-375/14-004
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.8 lb -
Body Style
Multipole-multiple actuator type -
Body Length
3.094 inches -
Body Width
2.000 inches -
Body Height
2.812 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Width
1.000 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.282 inches -
Pole Quantity
2 -
Mounting Facility Type And Quantity
4 terminal -
Storage Type
General purpose warehouse -
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal all locations -
Trip Release Characteristic
Instantaneous all locations and time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
2 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One and two linked -
Internal Trip Release Configuration
Series trip all locations -
Trip Delay Time In Seconds Per Rated Continuous Current
120.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant -
Trip Release Ambient Tempurature Rating
40.0 degrees celsius all locations -
Frequency In Hertz
60.0 all locations -
Test Data Document
81348-w-c-375 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.). -
Terminal Type And Quantity
2 compression and 2 quick disconnect, male -
Specification Data
81348-w-c-375/14 government specification
More from these suppliers
- 5975-00-245-9626 MPN WWC566Flexible Metal Conduit
- 5975-00-494-0670 MPN WS896Electrical Wall Plate
- 5935-01-044-0301 MPN WC596-8Electrical Plug Connector
- 5975-00-518-1721 MPN WJ800Junction Box
- 5935-00-480-7278 MPN W-C-596/76Electrical Plug Connector
- 5305-00-010-1181 MPN FFS92Machine Screw
- 5305-00-011-3717 MPN FFS111Wood Screw
- 5305-00-012-0505 MPN FFS85TYPE2STYLE10PHexagon Head Cap Screw
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-099-0693 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
W-C-375/14-004 | Federal Specifications |
W-C-375/14 | Federal Specifications |