NSN 5925-01-104-7975
Overload Switch
Multipole-multiple actuator type body style, plastic case material, moderately rugged fragility factor, pole quantity: 3.
Manufacturer part number M55629/5-246 for national stock number 5925011047975.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-104-7975.
-
MPN or Model
M55629/5-246
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.7 lb -
Body Style
Multipole-multiple actuator type -
Body Length
2.510 inches -
Body Width
Between 2.156 inches and 2.344 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.660 inches and 1.960 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.719 inches and 0.781 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.046 inches and 2.078 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.719 inches and 0.781 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.109 inches and 0.171 inches -
Mounting Surface To Terminal End Distance
2.553 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
6 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
40.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 at 200 pct all locations and 80.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant -
Frequency In Hertz
400.0 all locations -
Test Data Document
81349-mil-c-55629 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.). -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 threaded stud -
Specification Data
81349-mil-c-55629/5 government specification
More from these suppliers
- 5925-00-081-3823 MPN PSM333-0.75-240-400Circuit Breaker
- 5925-00-240-3424 MPN PCB832-0411CSKMG4-6-5A230VACC3Circuit Breaker
- 5925-00-502-7426 MPN 0411TSHX5-125VDC3Circuit Breaker
- 5925-00-845-8702 MPN X0411-50-240-60C1Circuit Breaker
- 5925-00-964-3983 MPN AM17-7.0Circuit Breaker
- 5925-00-981-2341 MPN 53-160-1MG3Circuit Breaker
- 5925-01-092-6289 MPN AM12HEMG6-5-32VDC4Circuit Breaker
- 5925-01-113-7793 MPN CD6-Z10-1Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-104-7975 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
M55629/5-246 | Military Specifications |
MIL-PRF-55629/5 | Military Specifications |
AM333MG6-40-208VAC400C14 | Eaton Corp |