NSN 5925-01-107-0844
Overload Switch
Multipole-single actuator type body style, plastic case material, 3 poles, maximum continuous load current rating per pole: 400.0 amperes ac all locations and 400.0 amperes dc all locations.
Manufacturer part number LA-36400 for national stock number 5925011070844.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-107-0844.
-
MPN or Model
LA-36400
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
14 lb -
Body Style
Multipole-single actuator type -
Body Length
10.750 inches -
Body Width
8.250 inches -
Body Height
4.062 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
9.531 inches -
Center To Center Distance Between Terminals Parallel To Width
2.750 inches -
Unthreaded Mounting Hole Diameter
0.312 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
9.531 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.750 inches -
Boss Height
0.250 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
4 unthreaded hole -
Maximum Continuous Load Current Rating Per Pole
400.0 amperes ac all locations and 400.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations and 250.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
25000.0 ac all locations and 10000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal-magnetic all locations -
Trip Release Characteristic
Instantaneous all locations and time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Trip Delay Time In Seconds Per Rated Continuous Current
90.000 at 200 pct all locations and 450.000 at 200 pct all locations -
Trip Release Ambient Tempurature Rating
40.0 degrees celsius all locations -
Frequency In Hertz
60.0 all locations -
Terminal Type And Quantity
6 compression
More from these suppliers
- 5950-00-075-8165 MPN 31021-400-63Electrical Coil
- 5930-00-781-9594 MPN TR51AREDPush Switch
- 5930-00-898-1815 MPN 222-10NH1-2221484Thermostatic Switch
- 5930-00-901-6517 MPN 9001BR11Push Switch
- 5930-01-367-6136 MPN SKS-46BH5Rotary Switch
- 5950-01-518-7326 MPN 9070-T1000D12Power Transformer
- 5930-01-626-3466 MPN 46040-485-50Sensitive Switch
- 5930-00-081-3611 MPN D222NBox Switch
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-107-0844 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
LA-36400 | Square D Co |
LA-36400 | Schneider Electric Usa, Inc. |