NSN 5925-01-107-8782
Overload Switch
Multipole-multiple actuator type body style, 0.164 inches mounting slot width, plastic case material, switch contact arrangement: single pole, double throw.
Manufacturer part number 260-4079-010 for national stock number 5925011078782.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-107-8782.
-
MPN or Model
260-4079-010
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
2 lb -
Body Style
Multipole-multiple actuator type -
Mounting Slot Width
0.164 inches -
Body Length
4.750 inches -
Body Width
Between 4.740 inches and 4.760 inches -
Body Height
2.609 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
3.547 inches -
Center To Center Distance Between Terminals Parallel To Width
1.026 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.026 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.219 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
6 threaded hole and 6 slot -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
80.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
140.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Switch Location And Position Designation
Internal at pole three -
Trip Delay Time In Seconds Per Rated Continuous Current
11.000 at 200 pct all locations and 100.500 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
5.0 ac and 1.0 dc -
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc -
Frequency In Hertz
400.0 all locations -
Unpackaged Unit Weight
2.000 pounds -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5905-00-005-2497 MPN 724-0639-880Film Fixed Resistor
- 5905-00-005-2901 MPN 724-1005-350Film Fixed Resistor
- 5905-00-064-3346 MPN 705-1468-840Film Fixed Resistor
- 5935-00-080-6959 MPN 371-0239-00Electrical Receptacle Connector
- 5935-00-103-1658 MPN 371-1284-220Electrical Receptacle Connector
- 5905-00-104-5765 MPN 712-0154-020Composition Fixed Resistor
- 5930-00-116-8711 MPN 259-0991-00Rotary Switch
- 5935-00-131-9591 MPN 357-9364-000Electrical Plug Connector
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-107-8782 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
260-4079-010 | Rockwell Collins, Inc. |
CD3-Z385-1 | Eaton Corp |
CD3-C3-80-240-1 | Eaton Corp |
Stock Check