NSN 5925-01-108-4246
Overload Switch
Multipole-single actuator type body style, metal case material, at 3 oclock and at 9 oclock nonturn device location, fragility factor: moderately rugged.
Manufacturer part number AP-112-1-40-602 for national stock number 5925011084246.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-108-4246.
-
MPN or Model
AP-112-1-40-602
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Thread Pitch Diameters
+0.3503/+0.3537 inches -
Body Style
Multipole-single actuator type -
Bushing Length
0.380 inches -
Body Length
1.562 inches -
Body Width
1.937 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
Between 0.860 inches and 0.890 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.610 inches and 0.640 inches -
Nonturn Device Location
At 3 oclock and at 9 oclock -
Nonturn Device Radius
Between 0.610 inches and 0.640 inches -
Nonturn Device Diameter
Between 0.235 inches and 0.265 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
1.780 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
6.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Instantaneous all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.375 inches -
Inclosure Protection Type For Which Designed
Hermetically sealed and shock resistant and vibration resistant -
Frequency In Hertz
400.0 all locations -
Unpackaged Unit Weight
5.400 ounces -
Thread Series Designator
Unef -
Terminal Type And Quantity
6 wire hook
More from these suppliers
- 5925-00-814-4087 MPN APL1-26469-3Circuit Breaker
- 5925-00-992-3240 MPN AP12-1-4-2-502Circuit Breaker
- 5925-01-020-9501 MPN UPL-111-1-42-153Circuit Breaker
- 5925-01-023-2996 MPN UPGH-11-1-61-203-01Circuit Breaker
- 5925-01-049-7364 MPN SM-C-350034Circuit Breaker
- 5925-01-099-4701 MPN UPGN-1-1-62-302Circuit Breaker
- 5925-01-132-6092 MPN UPL11-7007-65Circuit Breaker
- 5925-01-134-1235 MPN 295-11-1REC1-4459-030Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-108-4246 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AP-112-1-40-602 | Sensata Technologies Maryland, Inc |