NSN 5925-01-114-2907
Overload Switch
Multipole-multiple actuator type body style, plastic case material, moderately rugged fragility factor, pole quantity: 3.
Manufacturer part number AM333MG6-15-250-4-60 for national stock number 5925011142907.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-114-2907.
-
MPN or Model
AM333MG6-15-250-4-60
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-multiple actuator type -
Body Length
2.500 inches -
Body Width
2.250 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.938 inches -
Center To Center Distance Between Terminals Parallel To Width
0.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.140 inches -
Mounting Surface To Terminal End Distance
2.611 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
6 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
15.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 at 200 pct all locations and 10.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Frequency In Hertz
60.0 all locations -
Unpackaged Unit Weight
14.000 ounces -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5925-00-270-5967 MPN 3H900-6-8Circuit Breaker
- 5925-00-433-8594 MPN AM12-10-250-400-14Circuit Breaker
- 5925-00-570-4601 MPN 70-132-45MG6Circuit Breaker
- 5925-00-850-3506 MPN SM3-6R7-110VAC60CYCLESCURVE58Circuit Breaker
- 5925-00-890-8748 MPN AM12MG3Circuit Breaker
- 5925-01-024-3806 MPN AM12HK2-50VDCCURVECircuit Breaker
- 5925-01-032-5389 MPN AM333HEMG6-5-250-16-400Circuit Breaker
- 5925-01-066-6224 MPN HE3Z6-115Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-114-2907 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AM333MG6-15-250-4-60 | Eaton Corp |
Stock Check