NSN 5925-01-114-5185
Overload Switch
Single pole type body style, plastic case material, single pole, double throw switch contact arrangement, pole quantity: 1.
Manufacturer part number G383787-5 for national stock number 5925011145185.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-114-5185.
-
MPN or Model
G383787-5
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Body Length
2.500 inches -
Body Width
0.750 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.938 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches -
Switch Contact Arrangement
Single pole, double throw -
Boss Height
0.140 inches -
Mounting Surface To Terminal End Distance
2.997 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
2 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
11.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic-hydraulic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
0.180 at 200 pct single location and 0.500 at 200 pct single location -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
2.5 ac and 1.0 dc -
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc -
Unpackaged Unit Weight
4.250 ounces -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 threaded stud
More from these suppliers
- 5930-00-497-5639 MPN 3101-1313Slide Switch
- 5950-00-519-9914 MPN 181BTelephone Coil
- 5950-00-697-9366 MPN KS9136Pulse Transformer
- 5905-01-160-0032 MPN 471922-2422Film Fixed Resistor
- 5945-01-254-8411 MPN G391962Relay Assembly
- 5940-01-319-8163 MPN 184B2Terminal Board Assembly
- 5945-00-067-8609 MPN AF116RELAYElectromagnetic Relay
- 5940-00-147-1218 MPN 7663-1AElectrical Binding Post
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-114-5185 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
G383787-5 | Lucent Technologies Inc |
G383787-5 | American Telephone And Telegraph Co |
70-397-1MG6 | Eaton Corp |
G383787-5 | Lucent Technologies Inc |