1-321-802-5889

NSN 5925-01-116-5461

Overload Switch

About this product

Single pole type body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.

Manufacturer part number 31H4-100 for national stock number 5925011165461.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-01-116-5461.

  • MPN or Model

    31H4-100

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Unit Weight (Est.)
    0.1 lb
  • Body Style
    Single pole type
  • Bushing Length
    Between 0.458 inches and 0.478 inches
  • Body Length
    Between 1.294 inches and 1.310 inches
  • Body Width
    Between 0.670 inches and 0.690 inches
  • Case Material
    Plastic
  • Center To Center Distance Between Terminals Parallel To Length
    Between 1.095 inches and 1.155 inches
  • Fragility Factor
    Moderately rugged
  • Mounting Surface To Terminal End Distance
    Between 2.022 inches and 2.102 inches
  • Pole Quantity
    1
  • Mounting Facility Type And Quantity
    1 threaded bushing
  • Storage Type
    General purpose warehouse
  • Special Handling Feature
    Magnetic
  • Thready Qty Per Inch (tpi)
    32
  • Maximum Continuous Load Current Rating Per Pole
    10.0 amperes dc single location
  • Operating Voltage Type And Rating Per Pole In Volts
    32.0 dc single location
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    1000.0 dc single location
  • Circuit Protection Type
    Overcurrent single location
  • Trip Release Method
    Magnetic single location
  • Trip Release Characteristic
    Time delay single location
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    135.0 single location
  • Reset Method
    Manual
  • Main Contact Tripping Mechanism Type
    Trip free
  • Manual Actuator Type And Quantity
    1 toggle
  • Actuator Function
    Trip-reset
  • Actuator Position Designation
    Between pole one and two
  • Internal Trip Release Configuration
    Series trip single location
  • Thread Size
    0.500 inches
  • Trip Delay Time In Seconds Per Rated Continuous Current
    0.100 at 200 pct single location and 2.000 at 200 pct single location
  • Inclosure Protection Type For Which Designed
    Shock resistant and vibration resistant
  • Thread Series Designator
    Un
  • Terminal Type And Quantity
    2 quick disconnect, female
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-01-116-5461 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925011165461

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
31H4-100 Ellis & Watts International, Llc
T11-1-10.0A-02-31A-V Sensata Technologies Maryland, Inc
T11-0-10.0A-02-10-A Sensata Technologies Maryland, Inc
Stock Check
Availability of this NSN has not been updated recently. Submit the pricing and availbility form above to receive an up to date quote.