NSN 5925-01-118-0314
Overload Switch
Multipole-multiple actuator type body style, plastic case material, moderately rugged fragility factor, pole quantity: 3.
Manufacturer part number JC3-T3-15-2-BC for national stock number 5925011180314.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-118-0314.
-
MPN or Model
JC3-T3-15-2-BC
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-multiple actuator type -
Bushing Length
Between 0.098 inches and 0.162 inches -
Body Length
Between 1.968 inches and 2.032 inches -
Body Width
Between 1.468 inches and 1.532 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.528 inches and 1.592 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.718 inches and 0.782 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 1.628 inches and 1.692 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.718 inches and 0.782 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
Between 1.898 inches and 1.962 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
6 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 at 200 pct all locations and 22.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Dustproof -
Frequency In Hertz
50.0 all locations or 60.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 tab w/screw
More from these suppliers
- 5925-00-055-9372 MPN 3XAM17-2-5-208-60-54Circuit Breaker
- 5925-00-076-0120 MPN AM333MG6-10Circuit Breaker
- 5925-00-174-0872 MPN 0421-3Circuit Breaker
- 5925-00-192-5792 MPN JA3A2A3A3-15-2Circuit Breaker
- 5925-00-340-9982 MPN SM3-7-2-250-60-1Circuit Breaker
- 5925-00-595-8846 MPN AM2A3A10-2Circuit Breaker
- 5925-00-660-3897 MPN 3XAM1516MG3-1-416VAC11Circuit Breaker
- 5925-00-778-8819 MPN PXAM33MG6-15A250VAC60CYCCircuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-118-0314 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
JC3-T3-15-2-BC | Eaton Corp |