NSN 5925-01-118-7438
Overload Switch
Multipole-single actuator type body style, plastic case material, at 12 oclock and at 3 oclock and at 9 oclock nonturn device location, fragility factor: moderately rugged.
Manufacturer part number APGN-666-1-66-252 for national stock number 5925011187438.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-118-7438.
-
MPN or Model
APGN-666-1-66-252
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Thread Pitch Diameters
+0.4752/+0.4787 inches -
Body Style
Multipole-single actuator type -
Bushing Length
0.625 inches -
Body Length
2.000 inches -
Body Width
2.250 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.530 inches -
Center To Center Distance Between Terminals Parallel To Width
0.750 inches -
Nonturn Device Location
At 12 oclock and at 3 oclock and at 9 oclock -
Nonturn Device Radius
0.656 inches -
Nonturn Device Length
0.130 inches -
Nonturn Device Diameter
Between 0.151 inches and 0.161 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
2.232 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
2.5 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.500 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 at 200 pct all locations and 150.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Hermetically sealed and shock resistant and vibration resistant -
Frequency In Hertz
50.0 single location or 60.0 single location -
Unpackaged Unit Weight
9.000 ounces -
Thread Series Designator
Un -
Terminal Type And Quantity
6 tab w/screw
More from these suppliers
- 5925-00-307-4014 MPN APL-1-1-42-302Circuit Breaker
- 5925-00-487-6527 MPN APL111-1-4-2-203MCircuit Breaker
- 5925-00-900-5354 MPN 501I202Circuit Breaker
- 5925-01-051-3695 MPN APL111-2387-20Circuit Breaker
- 5925-01-068-0943 MPN AP-16-1-62-103Circuit Breaker
- 5925-01-112-0320 MPN AP112-1R7-2F1752Circuit Breaker
- 5925-01-156-7717 MPN UPL11-1R0-188-9Circuit Breaker
- 5925-01-160-7607 MPN AP-12-1-65F-502Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-118-7438 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
APGN-666-1-66-252 | Sensata Technologies Maryland, Inc |