NSN 5925-01-119-2006
Overload Switch
Multipole-single actuator type body style, plastic case material, 3 poles, arc quenching method: air.
Manufacturer part number AQB-A1601 for national stock number 5925011192006.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-119-2006.
-
MPN or Model
AQB-A1601
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-single actuator type -
Body Length
22.000 inches -
Body Width
16.000 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
13.625 inches -
Unthreaded Mounting Hole Diameter
0.406 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
19.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
4.000 inches -
Boss Height
0.875 inches -
Mounting Surface To Terminal End Distance
12.781 inches -
Pole Quantity
3 -
Arc Quenching Method
Air -
Mounting Facility Type And Quantity
8 unthreaded hole -
Storage Type
General purpose warehouse -
Maximum Continuous Load Current Rating Per Pole
1600.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
500.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
75000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal-magnetic all locations -
Trip Release Characteristic
Instantaneous all locations and time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 at 600 pct all locations and 32.000 at 600 pct all locations -
Inclosure Protection Type For Which Designed
Shock resistant and vibration resistant -
Trip Release Ambient Tempurature Rating
50.0 degrees celsius all locations -
Frequency In Hertz
60.0 all locations -
Terminal Type And Quantity
6 bus bar -
Nondefinitive Specification/std Data
Aqb-a1601 type
More from these suppliers
- 5905-00-001-2842 MPN RB18CE49R90FNoninductive Wire Wound Fixed Resistor
- 5905-00-001-5855 MPN MILR55182-5Film Fixed Resistor
- 5905-00-004-6278 MPN MILR55182-1Film Fixed Resistor
- 5905-00-005-2713 MPN MILR39007-9Inductive Wire Wound Fixed Resistor
- 5905-00-006-2990 MPN RNR55J2003FMFilm Fixed Resistor
- 5905-00-006-5576 MPN RNC60K1302FRFilm Fixed Resistor
- 5905-00-006-6941 MPN RNC60J4643BSFilm Fixed Resistor
- 5905-00-006-6981 MPN RNR60H2210FRFilm Fixed Resistor
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-119-2006 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AQB-A1601 | Military Specifications |