NSN 5925-01-120-1203
Overload Switch
Single pole type body style, plastic case material, at 12 oclock nonturn device location, nonturn device width: 0.110 inches .
Manufacturer part number 41-2-S14-LN2-3A for national stock number 5925011201203.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-120-1203.
-
MPN or Model
41-2-S14-LN2-3A
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.1 lb -
Body Style
Single pole type -
Bushing Length
0.250 inches -
Body Length
1.140 inches -
Body Width
0.550 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
0.790 inches -
Nonturn Device Location
At 12 oclock -
Nonturn Device Radius
0.370 inches -
Nonturn Device Length
0.060 inches -
Nonturn Device Width
0.110 inches -
Mounting Surface To Terminal End Distance
2.250 inches -
Pole Quantity
1 -
Mounting Facility Type And Quantity
1 threaded bushing -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
27 -
Maximum Continuous Load Current Rating Per Pole
3.0 amperes ac single location and 3.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac single location and 28.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
30.0 ac single location and 30.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
140.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 push-pull -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.375 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 at 200 pct single location and 65.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Frequency In Hertz
400.0 single location -
Unpackaged Unit Weight
1.410 ounces -
Thread Series Designator
Uns -
Terminal Type And Quantity
2 tab w/screw
More from these suppliers
- 5935-00-015-9266 MPN 942000-20Electrical Receptacle Connector
- 5950-00-067-6623 MPN 959148-1Reactor
- 5935-00-173-7843 MPN 436511-6Tip Jack
- 5935-00-617-6837 MPN 459876-1Tip Jack
- 5905-00-791-8938 MPN 437124-50Inductive Wire Wound Fixed Resistor
- 5905-00-920-6984 MPN 408900NNonprecision Nonwire Wound Variable Resistor
- 4920-01-008-3292 MPN 10046500-101Test Program Set
- 5945-01-022-4036 MPN 10088032-103Reed Relay
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-120-1203 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
41-2-S14-LN2-3A | Oakland Industries Ltd |
41-2-S14-LN2-3 | Oakland Industries Ltd |
10080928-102 | Honeywell International Inc. |