NSN 5925-01-125-5795
Overload Switch
Single pole type body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number AM1516MG3-30-28VDCC2 for national stock number 5925011255795.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-125-5795.
-
MPN or Model
AM1516MG3-30-28VDCC2
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Body Style
Single pole type -
Body Length
Between 3.709 inches and 3.729 inches -
Body Width
Between 0.980 inches and 1.000 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 3.053 inches and 3.073 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.740 inches and 2.760 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.146 inches and 0.166 inches -
Mounting Surface To Terminal End Distance
Between 2.229 inches and 2.249 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
2 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
30.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic-hydraulic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
130.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
2.200 at 200 pct single location and 7.500 at 200 pct single location -
Inclosure Protection Type For Which Designed
Fungus resistant -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 threaded stud
More from these suppliers
- 5925-00-345-6197 MPN AM33MG6-10A250V400CPSC15Circuit Breaker
- 5925-00-367-7620 MPN AM12MG3-20-120-4Circuit Breaker
- 5925-00-587-4154 MPN XAM33MG3-1-154-1Circuit Breaker
- 5925-00-928-6081 MPN 50-234-5-MG3Circuit Breaker
- 5925-00-932-3027 MPN 0111-10-250-60-3Circuit Breaker
- 5925-01-031-4861 MPN SM3-2-230VAC400C2Circuit Breaker
- 5925-01-051-2283 MPN HB3Z2-35Circuit Breaker
- 5925-01-118-1203 MPN W68X2Q1-2-3Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-125-5795 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AM1516MG3-30-28VDCC2 | Eaton Corp |
Stock Check
![](/public/images/partscage_shelf3.png)