NSN 5925-01-131-6792
Overload Switch
Multipole-multiple actuator type body style, plastic case material, 4 poles, arc quenching method: magnetic blowout.
Manufacturer part number UPL1111-7007-37 for national stock number 5925011316792.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-131-6792.
-
MPN or Model
UPL1111-7007-37
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-multiple actuator type -
Body Length
2.490 inches -
Body Width
3.000 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.940 inches -
Center To Center Distance Between Terminals Parallel To Width
0.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches -
Boss Height
0.150 inches -
Mounting Surface To Terminal End Distance
2.625 inches -
Pole Quantity
4 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
8 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
4 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, three, and four linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
6.000 at 100 pct all locations -
Inclosure Protection Type For Which Designed
General purpose -
Frequency In Hertz
400.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
8 threaded stud
More from these suppliers
- 5925-00-161-9167 MPN APL1R-778-26Circuit Breaker
- 5925-00-250-9748 MPN APL-111-1RE-42-252-MACircuit Breaker
- 5925-01-173-1115 MPN UPGH-66-1-61-50 2-0-Circuit Breaker
- 5925-01-198-7872 MPN 15005251Circuit Breaker
- 5925-01-237-1044 MPN AP-112-1-42F-252Circuit Breaker
- 5925-01-246-3522 MPN AP12-21274-1Circuit Breaker
- 5925-01-256-5852 MPN 203-2-1-61-103-E-1-1Circuit Breaker
- 5925-01-322-7930 MPN R25-2-2.00A-B121EVCircuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-131-6792 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
UPL1111-7007-37 | Sensata Technologies Maryland, Inc |
804685-37 | Raytheon Company |
Stock Check