NSN 5925-01-139-3140
Overload Switch
Plastic case material, moderately rugged fragility factor, 3 poles, arc quenching method: air.
Manufacturer part number ETN583100S36 for national stock number 5925011393140.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-139-3140.
-
MPN or Model
ETN583100S36
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
5 lb -
Body Length
11.000 inches -
Body Width
9.000 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
9.875 inches -
Center To Center Distance Between Terminals Parallel To Width
3.000 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
9.875 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
3.000 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.250 inches -
Mounting Surface To Terminal End Distance
9.281 inches -
Pole Quantity
3 -
Arc Quenching Method
Air -
Mounting Facility Type And Quantity
4 threaded hole -
Storage Type
General purpose warehouse -
Features Provided
Adjustable trip release -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
250.0 amperes ac all locations and 250.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
500.0 ac second location and 250.0 dc second location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
20000.0 ac second location and 15000.0 dc second location -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Instantaneous all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Adjustable Trip Setting Current Range Per Pole In Amps
+910.0/+1560.0 ac third location -
Internal Trip Release Configuration
Shunt trip third location -
Thread Size
0.250 inches -
Frequency In Hertz
60.0 third location -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5905-00-280-0092 MPN 176600PC1082Adjustable Resistor
- 5930-01-407-2149 MPN 711221PC239Rotary Switch
- 5985-01-599-6634 MPN 131505PC147ADirectional Coupler
- 5925-00-503-7390 MPN 176399Circuit Breaker
- 5925-00-867-7329 MPN ETN2771Circuit Breaker
- 5925-01-094-2720 MPN 701363-706254Circuit Breaker
- 5925-01-318-2377 MPN 704841SH1Circuit Breaker
- 5925-01-536-1604 MPN 705028/CD711613Marf Battery
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-139-3140 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
ETN583100S36 | Spd Electrical Systems, Inc |
315C574G18 WITH 452D377G17 | Eaton Corporation |
ETN583100S36 | Spd Electrical Systems, Inc |
315C574G18 WITH 452D377G17 | Eaton Corporation |
ETN583100S36 | Spd Electrical Systems, Inc |
315C574G18 WITH 452D377G17 | Eaton Corporation |