NSN 5925-01-152-6896
Overload Switch
Multipole-single actuator type body style, plastic case material, single pole, double throw switch contact arrangement, pole quantity: 3.
Manufacturer part number ETN-9719-20 for national stock number 5925011526896.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-152-6896.
-
MPN or Model
ETN-9719-20
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-single actuator type -
Body Length
4.125 inches -
Body Width
3.034 inches -
Body Height
3.375 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
2.625 inches -
Center To Center Distance Between Terminals Parallel To Width
1.125 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
0.625 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.938 inches -
Boss Height
0.125 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
6 clip -
Storage Type
General purpose warehouse -
Maximum Continuous Load Current Rating Per Pole
420.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
500.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
75000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal-magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Auxiliary Switch Function And Quantity
2 alarm -
Switch Location And Position Designation
Internal at pole two and internal at pole three -
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 at 600 pct all locations and 180.000 at 600 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant -
Trip Release Ambient Tempurature Rating
50.0 degrees celsius all locations -
Switch Terminal Type
Pin -
Switch Voltage Rating And Type In Volts
115.0 ac and 120.0 dc -
Frequency In Hertz
400.0 all locations -
Terminal Type And Quantity
6 compression
More from these suppliers
- 5950-01-136-6284 MPN 401388T1Transformer
- 5945-01-441-3700 MPN 61938-B0201 PC 18Electromagnetic Relay
- 5940-01-472-1367 MPN 741032K02Feedthru Terminal
- 5930-01-494-2370 MPN 116146-001Switch Actuator Adapter
- 5930-01-604-8300 MPN 120796-A00Dust And Moisture Seal Boot
- 5925-01-170-4136 MPN 199590-711022Circuit Breaker
- 5925-01-170-4138 MPN 199590-711021 MODCircuit Breaker
- 5925-01-233-5618 MPN 703876SH7Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-152-6896 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
ETN-9719-20 | Spd Electrical Systems, Inc |