NSN 5925-01-155-8518
Overload Switch
Multipole-single actuator type body style, plastic case material, double pole, double throw switch contact arrangement, pole quantity: 3.
Manufacturer part number ETN-5310-10 for national stock number 5925011558518.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-155-8518.
-
MPN or Model
ETN-5310-10
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
34.6 lb -
Body Style
Multipole-single actuator type -
Overall Height
10.032 inches -
Body Length
12.000 inches -
Body Width
9.000 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
9.875 inches -
Center To Center Distance Between Terminals Parallel To Width
3.000 inches -
Unthreaded Mounting Hole Diameter
0.250 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
9.875 inches -
Switch Contact Arrangement
Double pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
3.000 inches -
Boss Height
0.250 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
4 unthreaded hole -
Storage Type
General purpose warehouse -
Features Provided
Adjustable trip release -
Maximum Continuous Load Current Rating Per Pole
250.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
500.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
100000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal-magnetic all locations -
Trip Release Characteristic
Instantaneous all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Auxiliary Switch Function And Quantity
1 control -
Adjustable Trip Setting Current Range Per Pole In Amps
+1500.0/+3000.0 ac all locations -
Switch Location And Position Designation
Internal at pole one -
Inclosure Protection Type For Which Designed
Fungus resistant -
Trip Release Ambient Tempurature Rating
50.0 degrees celsius all locations -
Switch Terminal Type
Wire lead -
Switch Current Rating And Type In Amps
10.0 ac -
Switch Voltage Rating And Type In Volts
125.0 ac -
Frequency In Hertz
60.0 all locations -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5905-00-615-9066 MPN 650526FInductive Wire Wound Fixed Resistor
- 5930-00-646-9156 MPN 701348-6Rotary Switch
- 5930-01-494-6491 MPN 744954-K01Push Switch
- 5930-01-494-9187 MPN 705027PC1234Rotary Switch
- 5930-01-139-3686 MPN 178595-K1Toggle Switch
- 5930-01-521-3566 MPN 753187 REV M, ITEM 31Rotary Switch
- 5950-01-250-3249 MPN 782195-A00Power Transformer
- 5975-01-327-3245 MPN 719127-B22Cable Marker Sleeve
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-155-8518 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
ETN-5310-10 | Spd Electrical Systems, Inc |