NSN 5925-01-156-7721
Overload Switch
Multipole-multiple actuator type body style, 0.178 inches mounting slot width, plastic case material, switch contact arrangement: single pole, double throw.
Manufacturer part number CD2-B2-B5-100-2 for national stock number 5925011567721.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-156-7721.
-
MPN or Model
CD2-B2-B5-100-2
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
2 lb -
Body Style
Multipole-multiple actuator type -
Mounting Slot Width
0.178 inches -
Body Length
Between 5.769 inches and 5.831 inches -
Body Width
Between 2.041 inches and 2.103 inches -
Body Height
2.609 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 3.516 inches and 3.578 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.995 inches and 1.057 inches -
Unthreaded Mounting Hole Diameter
0.164 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.719 inches and 2.781 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.995 inches and 1.057 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.209 inches and 0.229 inches -
Mounting Surface To Terminal End Distance
Between 3.172 inches and 3.296 inches -
Pole Quantity
2 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
4 threaded hole and 2 unthreaded hole and 2 slot -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
100.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
125.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
2 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One and two linked -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 at 200 pct all locations and 6.500 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
5.0 ac and 1.0 dc -
Switch Voltage Rating And Type In Volts
125.0 ac and 50.0 dc -
Unpackaged Unit Weight
19.000 ounces -
Thread Series Designator
Unc -
Terminal Type And Quantity
4 threaded stud
More from these suppliers
- 5925-00-154-0314 MPN AM1516MG3-2-120-2-400Circuit Breaker
- 5925-00-189-4319 MPN SM5-3-250-400-1Circuit Breaker
- 5925-00-279-3479 MPN 3363SMG4-15-250-60-2Circuit Breaker
- 5925-00-308-7194 MPN AM333HEMG6-5-250VAC60-5Circuit Breaker
- 5925-00-762-0311 MPN FHC01-001-2Circuit Breaker
- 5925-00-823-2346 MPN 74-101-10Circuit Breaker
- 5925-00-838-4425 MPN AM333MG6-20-250VAC400C14Circuit Breaker
- 5925-00-950-4290 MPN 3363SMG4-15-230-60-1Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-156-7721 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
CD2-B2-B5-100-2 | Eaton Corp |