NSN 5925-01-157-7805
Overload Switch
0.164 inches mounting slot width, plastic case material, moderately rugged fragility factor, pole quantity: 3.
Manufacturer part number CD3-A3-70-240-1 for national stock number 5925011577805.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-157-7805.
-
MPN or Model
CD3-A3-70-240-1
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Mounting Slot Width
0.164 inches -
Body Length
Between 5.768 inches and 5.832 inches -
Body Width
Between 3.046 inches and 3.110 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 3.515 inches and 3.579 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.994 inches and 1.058 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.718 inches and 2.782 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.994 inches and 1.058 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.187 inches and 0.251 inches -
Mounting Surface To Terminal End Distance
Between 3.172 inches and 3.296 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
6 threaded hole and 6 slot -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
70.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
35.000 at 200 pct all locations and 105.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant -
Frequency In Hertz
50.0 all locations or 60.0 all locations -
Unpackaged Unit Weight
2.000 pounds -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5925-00-018-3225 MPN AM17-25-A-120-4-400Circuit Breaker
- 5925-00-081-3823 MPN PSM333-0-75-240VAC400Circuit Breaker
- 5925-00-718-7530 MPN X0411-60-240-60C1Circuit Breaker
- 5925-01-113-7793 MPN CD6-Z10-1Circuit Breaker
- 5925-01-145-4305 MPN AM12MG6-1R5-250VAC4Circuit Breaker
- 5925-01-265-0832 MPN AM3-Z397-2Circuit Breaker
- 5925-01-420-6923 MPN AM1-B3-30-3Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-157-7805 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
CD3-A3-70-240-1 | Eaton Corp |