Multipole-single actuator type body style, metal case material, 2 poles, maximum continuous load current rating per pole: 65.0 amperes dc all locations.

Manufacturer part number APGN-11-1-53-252 for national stock number 5925011584513.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-01-158-4513.

  • MPN or Model

    APGN-11-1-53-252

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Unit Weight (Est.)
    0.4 lb
  • Body Style
    Multipole-single actuator type
  • Bushing Length
    0.495 inches
  • Body Length
    2.000 inches
  • Body Width
    1.515 inches
  • Case Material
    Metal
  • Center To Center Distance Between Terminals Parallel To Length
    1.530 inches
  • Center To Center Distance Between Terminals Parallel To Width
    0.750 inches
  • End Application
    6920-01-142-2798
  • Mounting Surface To Terminal End Distance
    2.200 inches
  • Pole Quantity
    2
  • Mounting Facility Type And Quantity
    2 clip
  • Maximum Continuous Load Current Rating Per Pole
    65.0 amperes dc all locations
  • Operating Voltage Type And Rating Per Pole In Volts
    65.0 dc all locations
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    30.0 dc all locations
  • Circuit Protection Type
    Overvoltage all locations
  • Trip Release Method
    Thermal-magnetic all locations
  • Trip Release Characteristic
    Instantaneous all locations and time delay all locations
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    150.0 all locations
  • Ultimate Trip Time Per Pole In Seconds
    60.000 all locations
  • Reset Method
    Electric
  • Main Contact Tripping Mechanism Type
    Nontrip free
  • Manual Actuator Type And Quantity
    1 toggle
  • Actuator Function
    Trip-reset
  • Actuator Position Designation
    At pole two
  • External Actuator Linkage Arrangement
    One and two linked
  • Trip Release Duty Cycle
    Continuous all locations
  • Reset Actuator Voltage Rating And Type In Volts
    65.0 dc
  • Trip Release Ambient Tempurature Rating
    -40.0 degrees celsius all locations and 85.0 degrees celsius all locations
  • Terminal Type And Quantity
    1 screw
More from these suppliers
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-01-158-4513 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925011584513

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
APGN-11-1-53-252 Sensata Technologies Maryland, Inc
9353915 Us Army Ardec Rdecom
APGN-11-1-53-252 Sensata Technologies Maryland, Inc
9353915 Us Army Ardec Rdecom
Stock Check