NSN 5925-01-159-6599
Overload Switch
High inrush pole one only and pole four is a remote voltage trip application.
Manufacturer part number 29-512113-1 for national stock number 5925011596599.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-159-6599.
-
MPN or Model
29-512113-1
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
1 lb -
Body Style
Multipole-multiple actuator type -
Body Length
Between 2.490 inches and 2.510 inches -
Body Width
Between 2.960 inches and 3.040 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.928 inches and 1.948 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.740 inches and 0.760 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.052 inches and 2.072 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.740 inches and 0.760 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.130 inches and 0.150 inches -
Mounting Surface To Terminal End Distance
Between 2.403 inches and 2.533 inches -
Pole Quantity
4 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
8 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Features Provided
High inrush protection -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac first location -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac third location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc fourth location -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
130.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
4 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, three, and four linked -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip third location -
Thread Size
0.138 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 at 200 pct fourth location and 1.500 at 200 pct fourth location -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
10.0 ac and 4.0 dc -
Switch Voltage Rating And Type In Volts
250.0 ac and 30.0 dc -
Frequency In Hertz
400.0 third location -
Unpackaged Unit Weight
12.312 pounds -
Test Data Document
04655-29-512113 standard (includes industry or association standards, individual manufactureer standards, etc.). -
Thread Series Designator
Unc -
Terminal Type And Quantity
9 threaded stud
More from these suppliers
- 5935-00-957-8765 MPN 89-257229-3Receptacle Dummy Connector
- 5930-01-308-9299 MPN 33-1345224-21Push Switch
- 5935-01-469-0420 MPN 73-2729698-4Jack Box
- 5905-01-004-8651 MPN 36-553340-8000Inductive Wire Wound Fixed Resistor
- 6145-01-160-2253 MPN 19-512236-8Electrical Power Cable
- 5925-00-432-0546 MPN JA1-A2-A-15-2Circuit Breaker
- 5925-00-455-8584 MPN AM17-15-120-55-60Circuit Breaker
- 5925-00-686-0508 MPN 70-762-4-0AMPCircuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-159-6599 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
29-512113-1 | General Dynamics Mission Systems, |
AM4-Z82-1 | Eaton Corp |
Stock Check
![](/public/images/partscage_shelf3.png)