NSN 5925-01-159-6609
Overload Switch
Four terminals on pole one.
Manufacturer part number CD4-Z296-2W for national stock number 5925011596609.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-159-6609.
-
MPN or Model
CD4-Z296-2W
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
3.1 lb -
Body Style
Multipole-multiple actuator type -
Mounting Slot Width
0.164 inches -
Body Length
5.844 inches -
Body Width
3.096 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
3.546 inches -
Center To Center Distance Between Terminals Parallel To Width
1.032 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.032 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.218 inches -
Mounting Surface To Terminal End Distance
2.609 inches -
Pole Quantity
4 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
8 threaded hole and 8 slot -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
60.0 amperes ac third location -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac third location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac second location -
Circuit Protection Type
Undervoltage first location -
Trip Release Method
Magnetic-hydraulic third location -
Trip Release Characteristic
Time delay third location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
140.0 third location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
4 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, three, and four linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 at 200 pct third location and 10.000 at 200 pct third location -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Frequency In Hertz
400.0 third location -
Test Data Document
49956-g166010 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing) -
Thread Series Designator
Unc -
Terminal Type And Quantity
10 threaded stud
More from these suppliers
- 5905-00-723-3888 MPN 280MT040P037Inductive Wire Wound Fixed Resistor
- 5950-00-919-4539 MPN 160616Power Transformer
- 5950-00-933-5294 MPN 375M0381P065Radio Frequency Coil
- 5935-00-948-8582 MPN 217-1064P3Bracket Resistor
- 5940-00-950-1638 MPN BP101RElectrical Binding Post
- 5985-00-960-9080 MPN 3076-5012G1Waveguide Assembly
- 5905-01-039-8975 MPN 586370-9Nonprecision Nonwire Wound Variable Resistor
- 5985-01-054-2792 MPN 952830-1Radio Frequency Power Divider
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-159-6609 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
CD4-Z296-2W | Eaton Corporation |
G166010-1 | Raytheon Company |
CD4-Z296-2W | Heinemann Electric Canada |
CD4-Z160-1 | Eaton Corp |
G287573-1 | Raytheon Company |
G166010-1 | Raytheon Company |