NSN 5925-01-159-6612
Overload Switch
Multipole-multiple actuator type body style, plastic case material, moderately rugged fragility factor, pole quantity: 2.
Manufacturer part number 979212-4 for national stock number 5925011596612.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-159-6612.
-
MPN or Model
979212-4
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.5 lb -
Body Style
Multipole-multiple actuator type -
Body Length
Between 2.490 inches and 2.510 inches -
Body Width
Between 1.490 inches and 1.510 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.928 inches and 1.948 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.740 inches and 0.760 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.052 inches and 2.072 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.740 inches and 0.760 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.130 inches and 0.150 inches -
Mounting Surface To Terminal End Distance
Between 2.461 inches and 2.481 inches -
Pole Quantity
2 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
4 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
2.0 amperes dc first location -
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc first location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc first location -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
2 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One and two linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 at 200 pct all locations and 20.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Frequency In Hertz
400.0 second location -
Unpackaged Unit Weight
6.500 ounces -
Test Data Document
49956-979212 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing) -
Thread Series Designator
Unc -
Terminal Type And Quantity
4 threaded stud
More from these suppliers
- 5985-00-005-2963 MPN 482587-4Waveguide Assembly
- 5905-00-117-4192 MPN 280-1015P104Composition Fixed Resistor
- 5940-00-155-7663 MPN 227-1035P3Lug Terminal
- 5975-00-402-7281 MPN 152272-12Electrical Tiedown Mounting Base
- 5950-00-414-3147 MPN 363507-1Audio Frequency Transformer
- 5905-00-428-4323 MPN 280MR033P264Film Fixed Resistor
- 5935-00-470-2009 MPN 581507Electrical Receptacle Connector
- 5950-00-617-4095 MPN 292-4917G1Power Transformer
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-159-6612 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
979212-4 | Raytheon Company |
AM2-Z229-4 | Eaton Corp |
979212-4 | Raytheon Company |
979212-4 | Raytheon Company |