NSN 5925-01-161-2945
Overload Switch
Multipole-multiple actuator type body style, plastic case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number 2567-249-00 for national stock number 5925011612945.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-161-2945.
-
MPN or Model
2567-249-00
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.8 lb -
Body Style
Multipole-multiple actuator type -
Body Length
Between 5.769 inches and 5.831 inches -
Body Width
Between 2.041 inches and 2.103 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 3.516 inches and 3.578 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.995 inches and 1.057 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.719 inches and 2.781 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.995 inches and 1.057 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.209 inches and 0.229 inches -
Mounting Surface To Terminal End Distance
Between 3.172 inches and 3.265 inches -
Pole Quantity
2 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
4 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Features Provided
High inrush protection -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac first location -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac first location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac first location -
Circuit Protection Type
Overvoltage second location -
Trip Release Method
Magnetic-hydraulic first location -
Trip Release Characteristic
Time delay first location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
120.0 second location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
2 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One and two linked -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Relay trip second location -
Thread Size
0.138 inches -
Switch Location And Position Designation
External at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 at 200 pct first location and 70.000 at 200 pct first location -
Inclosure Protection Type For Which Designed
Dustproof -
Switch Terminal Type
Turret -
Switch Current Rating And Type In Amps
2.5 ac and 1.0 dc -
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc -
Frequency In Hertz
50.0 first location or 60.0 first location -
Unpackaged Unit Weight
11.000 ounces -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5925-00-155-2587 MPN AM333MG6-18-250VAC-15-400HZCircuit Breaker
- 5925-00-204-9758 MPN AM12M6-2Circuit Breaker
- 5925-00-521-0389 MPN AM33MG6-4.5-250-60HZ-5Circuit Breaker
- 5925-00-725-8811 MPN AM12MG3-5-74Circuit Breaker
- 5925-00-732-7530 MPN AM12MG6-7-5-50VDC5Circuit Breaker
- 5925-00-800-0021 MPN AM13HKMG3-0.50-115-60-5Circuit Breaker
- 5925-00-964-4895 MPN AM444MG6-0-3-250VAC400C14Circuit Breaker
- 5925-01-039-6220 MPN AM1-A3-A40-2Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-161-2945 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
2567-249-00 | Lorain Electronics Corp |
2567-249 | Reliance Comm/tec Corp |
CD2-A9-A16-DU | Eaton Corp |