NSN 5925-01-161-5846
Overload Switch
Multipole-multiple actuator type body style, plastic case material, 4 poles, storage type: general purpose warehouse.
Manufacturer part number 229-4-1-41F-4-9-100 for national stock number 5925011615846.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-161-5846.
-
MPN or Model
229-4-1-41F-4-9-100
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
3.5 lb -
Body Style
Multipole-multiple actuator type -
Body Length
5.800 inches -
Body Width
4.144 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
3.550 inches -
Center To Center Distance Between Terminals Parallel To Width
1.026 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.026 inches -
Boss Height
0.220 inches -
Mounting Surface To Terminal End Distance
3.550 inches -
Pole Quantity
4 -
Mounting Facility Type And Quantity
8 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
100.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
4 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, three, and four linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.300 at 200 pct all locations and 1.500 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant -
Frequency In Hertz
400.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
8 threaded stud
More from these suppliers
- 5930-01-586-0928 MPN AP1-1-51-502Toggle Switch
- 5925-00-260-4298 MPN AP12-1406-1Circuit Breaker
- 5925-00-274-3195 MPN APL111-561-410Circuit Breaker
- 5925-00-308-7194 MPN APL-111-1R0-55629/6-046Circuit Breaker
- 5925-01-025-4397 MPN APGX-6-2656-1Circuit Breaker
- 5925-01-031-4861 MPN AP1-2-1-115VAC400Circuit Breaker
- 5925-01-181-8982 MPN 203-1-7761-9Circuit Breaker
- 5925-01-220-5497 MPN APGN-666-1-41-253-00Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-161-5846 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
229-4-1-41F-4-9-100 | Sensata Technologies Maryland, Inc |