NSN 5925-01-163-2901
Overload Switch
Single pole type body style, 0.178 inches mounting slot width, plastic case material, fragility factor: moderately rugged.
Manufacturer part number 5050212-1 for national stock number 5925011632901.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-163-2901.
-
MPN or Model
5050212-1
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.7 lb -
Body Style
Single pole type -
Mounting Slot Width
0.178 inches -
Body Length
5.800 inches -
Body Width
1.026 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
3.547 inches -
Unthreaded Mounting Hole Diameter
0.164 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches -
Fragility Factor
Moderately rugged -
End Application
5411-01-130-3793 -
Boss Height
0.219 inches -
Mounting Surface To Terminal End Distance
3.324 inches -
Pole Quantity
1 -
Arc Quenching Method
Air -
Mounting Facility Type And Quantity
2 threaded hole and 1 unthreaded hole and 1 slot -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
100.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
125.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic-hydraulic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
35.000 at 200 pct single location and 100.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Unpackaged Unit Weight
9.000 ounces -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 threaded stud
More from these suppliers
- 5975-01-158-4047 MPN 5051694-1Electrical-electronic Equipment Panel
- 5945-00-866-8559 MPN 363T9Electromagnetic Relay
- 5945-01-461-9926 MPN 9-1811-14Electromagnetic Relay
- 5925-00-318-3023 MPN AMI-Z21-092Circuit Breaker
- 5925-00-497-4293 MPN AM333-5-240-400-16Circuit Breaker
- 5925-00-690-1741 MPN AM17-3-5-120VAC4Circuit Breaker
- 5925-00-825-4688 MPN 1163SVMG4-1AMP416VACTDC12Circuit Breaker
- 5925-00-876-4070 MPN 50-264-1-MG3Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-163-2901 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
5050212-1 | Signals Warfare Project Manager |
CD1-B2-U100-1 | Eaton Corp |