NSN 5925-01-163-9088
Overload Switch
Single pole type body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number T11-U61-1-3AMP for national stock number 5925011639088.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-163-9088.
-
MPN or Model
T11-U61-1-3AMP
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Body Length
0.740 inches -
Body Width
0.430 inches -
Body Height
1.360 inches -
Case Material
Plastic -
Fragility Factor
Moderately rugged -
End Application
4920-01-066-4155 -
Boss Height
0.250 inches -
Pole Quantity
1 -
Mounting Facility Type And Quantity
2 clip -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Maximum Continuous Load Current Rating Per Pole
3.0 amperes ac single location and 3.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location and 24.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
30.0 ac single location and 30.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Thermal single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 push button -
Actuator Function
Reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 at 200 pct single location and 10.000 at 200 pct single location -
Trip Release Ambient Tempurature Rating
50.0 degrees celsius single location -
Frequency In Hertz
60.0 single location -
Terminal Type And Quantity
2 quick disconnect, male
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-163-9088 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
T11-U61-1-3AMP | Inmark Corp |