NSN 5925-01-165-2915
Overload Switch
Flush mtg hardware incl; illuminated handle red.
Manufacturer part number 203-2-2-66-302-4-1-1A for national stock number 5925011652915.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-165-2915.
-
MPN or Model
203-2-2-66-302-4-1-1A
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Body Length
2.000 inches -
Body Width
0.920 inches -
Body Height
1.770 inches -
Case Material
Plastic -
Switch Contact Arrangement
Single pole, double throw -
Boss Height
0.125 inches -
Pole Quantity
1 -
Mounting Facility Type And Quantity
2 clip -
Maximum Continuous Load Current Rating Per Pole
3.5 amperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic-hydraulic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Ultimate Trip Time Per Pole In Seconds
30.000 single location and 130.000 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip single location -
Switch Location And Position Designation
External at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 at 200 pct single location and 18.000 at 200 pct single location and 0.600 at 400 pct single location and 4.000 at 400 pct single location and 0.015 at 800 pct single location and 0.300 at 800 pct single location -
Switch Terminal Type
Turret -
Switch Current Rating And Type In Amps
10.0 ac -
Switch Voltage Rating And Type In Volts
250.0 ac -
Frequency In Hertz
50.0 single location or 60.0 single location -
Terminal Type And Quantity
2 tab, solder lug
More from these suppliers
- 5925-01-047-7510 MPN A01-76-10Circuit Breaker
- 5925-01-100-0636 MPN AP1-2508-6Circuit Breaker
- 5925-01-141-6683 MPN AP-12-1R-62F-1751Circuit Breaker
- 5925-01-145-5328 MPN APL1112-8918-2Circuit Breaker
- 5925-01-161-7317 MPN AP1-7923-1Circuit Breaker
- 5925-01-291-4018 MPN 203-22-1-64F-502-4-1-13Circuit Breaker
- 5925-01-320-9904 MPN 203-2-1-66-103-6-3-5Circuit Breaker
- 5925-01-364-9183 MPN AP117-1R-71F-802Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-165-2915 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
203-2-2-66-302-4-1-1A | Sensata Technologies Maryland, Inc |