NSN 5925-01-165-9912
Overload Switch
Single pole type body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number TX1-P05-L05-WH1 for national stock number 5925011659912.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-165-9912.
-
MPN or Model
TX1-P05-L05-WH1
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Body Length
1.780 inches -
Body Width
0.700 inches -
Body Height
1.630 inches -
Case Material
Plastic -
Fragility Factor
Moderately rugged -
Boss Height
0.320 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
2 clip -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Features Provided
High inrush protection -
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac single location and 5.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac single location and 32.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac single location and 1000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Thermal single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
140.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Trip Delay Time In Seconds Per Rated Continuous Current
6.000 at 200 pct single location and 41.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
General purpose -
Trip Release Ambient Tempurature Rating
40.0 degrees celsius single location -
Frequency In Hertz
50.0 single location or 60.0 single location -
Unpackaged Unit Weight
1.000 ounces -
Terminal Type And Quantity
2 tab, solder lug
More from these suppliers
- 5945-00-103-5138 MPN C231AElectromagnetic Relay
- 5925-00-142-0752 MPN AM12MG6-20A28VDCCircuit Breaker
- 5925-00-253-5137 MPN AM17-40-32-54-DCCircuit Breaker
- 5925-00-279-1036 MPN 50-127MG3-6-120AC2Circuit Breaker
- 5925-00-810-3736 MPN AM12HKMG6-10-50VDC4Circuit Breaker
- 5925-00-845-5068 MPN 50-110-8MG3Circuit Breaker
- 5925-01-096-4665 MPN SM333-7-5-240VAC400C2Circuit Breaker
- 5925-01-185-5257 MPN CD6-A3-U-30-240-50/60-1Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-165-9912 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
TX1-P05-L05-WH1 | Eaton Corp |