NSN 5925-01-171-1671
Overload Switch
Multipole-multiple actuator type body style, plastic case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number 219-2-4505-2 for national stock number 5925011711671.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-171-1671.
-
MPN or Model
219-2-4505-2
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
1.6 lb -
Body Style
Multipole-multiple actuator type -
Body Length
4.750 inches -
Body Width
2.063 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
3.550 inches -
Center To Center Distance Between Terminals Parallel To Width
1.032 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.032 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.220 inches -
Mounting Surface To Terminal End Distance
3.765 inches -
Pole Quantity
2 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
4 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
7.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
2 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One and two linked -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Shunt trip first location -
Thread Size
0.138 inches -
Switch Location And Position Designation
External at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 at 500 pct first location -
Inclosure Protection Type For Which Designed
General purpose -
Switch Terminal Type
Turret -
Switch Current Rating And Type In Amps
2.5 ac and 1.0 dc -
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc -
Frequency In Hertz
50.0 all locations or 60.0 all locations -
Unpackaged Unit Weight
11.000 ounces -
Thread Series Designator
Unc -
Terminal Type And Quantity
5 threaded stud
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-171-1671 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
219-2-4505-2 | Vdo Control Systems Inc |
2567-219 | Reliance Comm/tec Corp |