NSN 5925-01-174-8775
Overload Switch
Multipole-multiple actuator type body style, plastic case material, moderately rugged fragility factor, pole quantity: 3.
Manufacturer part number JA3-Z50-1 for national stock number 5925011748775.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-174-8775.
-
MPN or Model
JA3-Z50-1
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.3 lb -
Body Style
Multipole-multiple actuator type -
Body Length
Between 1.985 inches and 2.015 inches -
Body Width
Between 2.245 inches and 2.255 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.555 inches and 1.565 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.745 inches and 0.755 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 1.655 inches and 1.665 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.745 inches and 0.755 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.125 inches and 0.135 inches -
Mounting Surface To Terminal End Distance
Between 1.835 inches and 1.845 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
6 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay first location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Internal Trip Release Configuration
Shunt trip second location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.200 at 200 pct third location and 2.000 at 200 pct third location -
Inclosure Protection Type For Which Designed
Dustproof -
Frequency In Hertz
400.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 tab, solder lug
More from these suppliers
- 5925-00-826-8887 MPN 71-179-1-MG6Circuit Breaker
- 5925-00-959-6075 MPN SM3-10-50VDC57Circuit Breaker
- 5925-00-981-2341 MPN 53-160-1MG3Circuit Breaker
- 5925-01-021-3114 MPN AM333MG6-10-250V-60HZ-5Circuit Breaker
- 5925-01-096-4681 MPN AM333MG6-40-250VAC60C5Circuit Breaker
- 5925-01-145-5330 MPN AM4-Z108-1Circuit Breaker
- 5925-01-160-6240 MPN CD3-Z346-1Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-174-8775 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
JA3-Z50-1 | Eaton Corp |