NSN 5925-01-175-5057
Overload Switch
Actuator black with white markings.
Manufacturer part number APG-66-1-62-203-01 for national stock number 5925011755057.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-175-5057.
-
MPN or Model
APG-66-1-62-203-01
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.3 lb -
Thread Pitch Diameters
+0.1177/+0.1214 inches -
Body Style
Multipole-single actuator type -
Body Length
2.000 inches -
Body Width
1.515 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.530 inches -
Center To Center Distance Between Terminals Parallel To Width
0.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.130 inches -
Mounting Surface To Terminal End Distance
2.000 inches -
Pole Quantity
2 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
4 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
277.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 at 200 pct single location and 20.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Hermetically sealed and shock resistant and vibration resistant -
Frequency In Hertz
50.0 all locations or 60.0 all locations -
Unpackaged Unit Weight
4.400 ounces -
Thread Series Designator
Unc -
Terminal Type And Quantity
4 tab w/screw
More from these suppliers
- 5930-01-435-4266 MPN UPL-000-26644-1Toggle Switch
- 5925-00-069-6535 MPN AP-1-4-51-402Circuit Breaker
- 5925-00-096-4360 MPN APGN-6-1-51-353Circuit Breaker
- 5925-00-425-6228 MPN 2282221-28Circuit Breaker
- 5925-01-160-7607 MPN AP-12-1-65F-502Circuit Breaker
- 5925-01-175-5055 MPN 209-2-1-52-2-8-2Circuit Breaker
- 5925-01-197-8403 MPN APG-6-20454-1Circuit Breaker
- 5925-01-294-8330 MPN AP112-1R-21612-1Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-175-5057 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
APG-66-1-62-203-01 | Sensata Technologies Maryland, Inc |