NSN 5925-01-176-0922
Overload Switch
Single pole type body style, plastic case material, 1 poles, thready qty per inch (tpi): 32.
Manufacturer part number 7274-52-1/2 for national stock number 5925011760922.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-176-0922.
-
MPN or Model
7274-52-1/2
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Thread Pitch Diameters
+0.444/+0.447 inches -
Body Style
Single pole type -
Bushing Length
Between 0.328 inches and 0.390 inches -
Body Length
Between 0.719 inches and 0.781 inches -
Body Width
Between 0.531 inches and 0.593 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 0.742 inches and 0.804 inches -
Mounting Surface To Terminal End Distance
1.608 inches -
Pole Quantity
1 -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac single location and 2.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location and 30.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 ac single location and 2000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Thermal single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
145.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 push-pull -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.438 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 at 200 pct single location and 20.000 at 200 pct single location and 0.160 at 500 pct single location and 1.000 at 500 pct single location and 0.046 at 1000 pct single location and 0.200 at 1000 pct single location -
Inclosure Protection Type For Which Designed
Explosion proof -
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location -
Frequency In Hertz
60.0 single location or 400.0 single location -
Thread Series Designator
Uns -
Terminal Type And Quantity
2 screw
More from these suppliers
- 5945-00-247-9540 MPN MRA6902-313Electromagnetic Relay
- 5930-00-490-5235 MPN M221F-163-0305-21Thermostatic Switch
- 5930-01-067-5882 MPN M1192180282Thermostatic Switch
- 5930-01-127-9218 MPN 20425-L96-89-903Thermostatic Switch
- 5930-01-163-8688 MPN 5189724Sensitive Switch
- 5930-01-496-9417 MPN M1110090484Thermostatic Switch
- 5930-01-523-1818 MPN 11041-51Thermostatic Switch
- 5930-01-568-5310 MPN M211L146030421Thermostatic Switch
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-176-0922 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
7274-52-1/2 | Sensata Technologies, Inc |