NSN 5925-01-187-7404
Overload Switch
Plastic case material, moderately rugged fragility factor, 1 poles, storage type: general purpose warehouse.
Manufacturer part number JA1A3A7-2 for national stock number 5925011877404.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-187-7404.
-
MPN or Model
JA1A3A7-2
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Case Material
Plastic -
Fragility Factor
Moderately rugged -
Pole Quantity
1 -
Storage Type
General purpose warehouse -
Maximum Continuous Load Current Rating Per Pole
7.0 amperes ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Internal Trip Release Configuration
Series trip single location -
Inclosure Protection Type For Which Designed
General purpose
More from these suppliers
- 5945-00-827-1722 MPN AN1-522XBX24VDC-10-SECElectromagnetic Relay
- 5925-00-038-5894 MPN AM1-A3-A-10-2Circuit Breaker
- 5925-00-067-3359 MPN 3XAM17-20-208AC56-400HZCircuit Breaker
- 5925-00-081-8720 MPN SM333-10-250VAC400C2Circuit Breaker
- 5925-00-429-1628 MPN AM33HKMG3-2-230VAC4Circuit Breaker
- 5925-00-502-9274 MPN X0411-501-120-60-9Circuit Breaker
- 5925-00-508-0540 MPN 2263S30A230VAC60-3Circuit Breaker
- 5925-00-835-2059 MPN 3XAM17-10-115-55Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-187-7404 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
JA1A3A7-2 | Eaton Corp |
08-1-000036 | Nicolet |
Stock Check
![](/public/images/partscage_shelf3.png)