NSN 5925-01-187-7405
Overload Switch
Multipole-multiple actuator type body style, plastic case material, 3 poles, arc quenching method: magnetic blowout.
Manufacturer part number GJ3-A3-DUW-100-240-1 for national stock number 5925011877405.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-187-7405.
-
MPN or Model
GJ3-A3-DUW-100-240-1
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-multiple actuator type -
Body Length
7.125 inches -
Body Width
4.500 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
5.625 inches -
Center To Center Distance Between Terminals Parallel To Width
1.500 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.828 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.500 inches -
Boss Height
0.219 inches -
Mounting Surface To Terminal End Distance
3.594 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
6 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
100.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
18000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.190 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
22.000 at 200 pct all locations and 150.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant -
Frequency In Hertz
50.0 all locations or 60.0 all locations -
Thread Series Designator
Unf -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5925-00-081-9135 MPN 70-667MG3-24Circuit Breaker
- 5925-00-088-9502 MPN AM-12-760-12AMPCircuit Breaker
- 5925-00-170-4083 MPN GB3-A3-1.75-1Circuit Breaker
- 5925-00-306-2836 MPN AM12HK5A50VDC5Circuit Breaker
- 5925-00-324-0142 MPN PSM6-20-250AC50DCRT18DC50MALKTABCircuit Breaker
- 5925-00-433-9082 MPN GJ3-G3-225-250-2Circuit Breaker
- 5925-00-790-3799 MPN 70-132-17MG6-10-50-250VAC4Circuit Breaker
- 5925-00-827-4937 MPN 2XAM1516-100Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-187-7405 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
GJ3-A3-DUW-100-240-1 | Heinemann Electric Canada |
7909833-00 | Lockheed Martin Corporation |
GJ3-A3-DU-100-240-1 | Eaton Corp |