NSN 5925-01-188-4301
Overload Switch
Multipole-multiple actuator type body style, plastic case material, moderately rugged fragility factor, pole quantity: 4.
Manufacturer part number 10M10-262 for national stock number 5925011884301.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-188-4301.
-
MPN or Model
10M10-262
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
1.5 lb -
Body Style
Multipole-multiple actuator type -
Body Length
Between 2.490 inches and 2.510 inches -
Body Width
Between 2.990 inches and 3.010 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.928 inches and 1.948 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.740 inches and 0.760 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.052 inches and 2.062 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.740 inches and 0.760 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.130 inches and 0.150 inches -
Mounting Surface To Terminal End Distance
Between 2.461 inches and 2.481 inches -
Pole Quantity
4 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
8 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
4 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, three, and four linked -
Internal Trip Release Configuration
Series trip third location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 at 200 pct all locations and 20.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Frequency In Hertz
50.0 all locations or 60.0 all locations -
Unpackaged Unit Weight
12.500 ounces -
Thread Series Designator
Unc -
Terminal Type And Quantity
10 threaded stud
More from these suppliers
- 5925-00-491-2313 MPN JA1-B3-A-2-PCircuit Breaker
- 5925-00-584-6242 MPN AM3A3A20-2Circuit Breaker
- 5925-00-800-1061 MPN 64-184-1MG4-60-416-2-400Circuit Breaker
- 5925-00-884-0672 MPN 70-868MG3-1-250AC5Circuit Breaker
- 5925-01-089-9443 MPN HE1Z7-68Circuit Breaker
- 5925-01-131-9776 MPN CD2A8-30-240-10Circuit Breaker
- 5925-01-222-0833 MPN CD1-Z262-3Circuit Breaker
- 5925-01-321-7183 MPN 1135758G3Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-188-4301 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
10M10-262 | Boeing Company, The |
UPL9111-23722-2 | Sensata Technologies Maryland, Inc |
AM4-Z1 48-1 | Eaton Corp |
AM4-A3A3A3A18-A-30-2 | Eaton Corp |
AM4-A3A3A3A18-A-30-2 P4-107VRDC | Eaton Corp |
IULHK9111-23722-2 | Sensata Technologies, Inc |
Stock Check
![](/public/images/partscage_shelf3.png)