NSN 5925-01-189-7510
Overload Switch
Multipole-multiple actuator type body style, 0.164 inches mounting slot width, plastic case material, switch contact arrangement: single pole, double throw.
Manufacturer part number 5541996-3 for national stock number 5925011897510.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-189-7510.
-
MPN or Model
5541996-3
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
3 lb -
Body Style
Multipole-multiple actuator type -
Mounting Slot Width
0.164 inches -
Body Length
5.844 inches -
Body Width
3.093 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
3.546 inches -
Center To Center Distance Between Terminals Parallel To Width
1.032 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.032 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.218 inches -
Mounting Surface To Terminal End Distance
2.609 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
6 threaded hole and 6 slot -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Features Provided
High inrush protection -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
480.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
45.000 at 200 pct all locations and 200.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Humidity resistant and salt spray proof and shock resistant and humidity resistant and fungus resistant and vibration resistant -
Switch Terminal Type
Turret -
Switch Current Rating And Type In Amps
10.0 ac and 4.0 dc -
Switch Voltage Rating And Type In Volts
250.0 ac and 30.0 dc -
Frequency In Hertz
50.0 all locations or 60.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5950-00-147-7525 MPN 2678617REVDPower Transformer
- 4820-00-375-8218 MPN 6800-799347PCV2Globe Valve
- 4820-00-382-7842 MPN K1-3801-1000424PCALLVacuum Breaking Valve
- 4820-00-405-9718 MPN S4824-1385541Stop-check Valve
- 4820-00-446-3321 MPN YMS135S49-45PC143T0154Safety Relief Valve
- 5930-00-528-6914 MPN 3183219Sensitive Switch
- 5935-00-808-7620 MPN 1667928-32Electrical Receptacle Connector
- 5945-00-823-2527 MPN 12Z13001-7777Electromagnetic Relay
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-189-7510 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
5541996-3 | Naval Sea Systems Command |
CD3-A9A8A8-AB-15-480-100 | Eaton Corp |