Overload Switch
Multipole-multiple actuator type body style, plastic case material, 4 poles, thready qty per inch (tpi): 32.
Manufacturer part number 6403492-1 for national stock number 5925011947532.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-194-7532.
-
MPN or Model
6403492-1
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
1 lb -
Body Style
Multipole-multiple actuator type -
Body Length
2.490 inches -
Body Width
3.030 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.940 inches -
Center To Center Distance Between Terminals Parallel To Width
0.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches -
End Application
4920-01-111-2981 -
Boss Height
0.150 inches -
Mounting Surface To Terminal End Distance
2.475 inches -
Pole Quantity
4 -
Mounting Facility Type And Quantity
8 threaded hole -
Features Provided
High inrush protection -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac second location -
Operating Voltage Type And Rating Per Pole In Volts
32.0 dc third location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc third location -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
4 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, three, and four linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.700 at 200 pct third location and 10.000 at 200 pct third location -
Inclosure Protection Type For Which Designed
Fungus proof -
Frequency In Hertz
50.0 second location or 60.0 second location -
Thread Series Designator
Unc -
Terminal Type And Quantity
8 threaded stud
More from these suppliers
- 5945-00-079-5350 MPN 400698-3Electromagnetic Relay
- 5950-00-917-7679 MPN Q71349-7Power Autotransformer Transformer
- 5935-01-338-3610 MPN 6456333-1Electrical Connector Backshell
- 4920-01-342-5914 MPN 6419997-1Receptacle Moun Bracket Assembly
- 4920-01-005-0262 MPN 2134802-1Bolt And Chain Asse
- 5985-01-265-0966 MPN 6406808-2Radio Frequency Transmission Line Switch
- 5925-01-386-3178 MPN 3598044-2Circuit Breaker
- 5925-00-224-6070 MPN APL-1-1R0-51-103-MCircuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-194-7532 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
6403492-1 | Honeywell Intl Inc |
APL-1111-20509-1 | Sensata Technologies Maryland, Inc |