NSN 5925-01-197-2585
Overload Switch
Multipole-multiple actuator type body style, 0.164 inches mounting slot width, plastic case material, switch contact arrangement: single pole, double throw.
Manufacturer part number CD2-C2C3-15-240-1 for national stock number 5925011972585.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-197-2585.
-
MPN or Model
CD2-C2C3-15-240-1
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-multiple actuator type -
Mounting Slot Width
0.164 inches -
Body Length
Between 5.769 inches and 5.831 inches -
Body Width
Between 2.041 inches and 2.103 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 3.516 inches and 3.578 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 1.016 inches and 1.036 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.719 inches and 2.781 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 1.016 inches and 1.036 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.209 inches and 0.229 inches -
Mounting Surface To Terminal End Distance
Between 3.172 inches and 3.296 inches -
Pole Quantity
2 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
4 threaded hole and 4 slot -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
2 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One and two linked -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
35.000 at 200 pct all locations and 150.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
10.0 ac and 4.0 dc -
Switch Voltage Rating And Type In Volts
250.0 ac and 30.0 dc -
Frequency In Hertz
400.0 all locations -
Unpackaged Unit Weight
2.000 pounds -
Thread Series Designator
Unc -
Terminal Type And Quantity
4 threaded stud
More from these suppliers
- 5945-01-432-9322 MPN C-180-3Electromagnetic Relay
- 5930-00-518-0033 MPN 35-489M6Toggle Switch
- 5925-00-257-9043 MPN HB3Z2-70Circuit Breaker
- 5925-00-260-4298 MPN 78-166-1Circuit Breaker
- 5925-00-265-5807 MPN 6CURVE2Circuit Breaker
- 5925-00-430-6343 MPN CF2G3U50-240-9Circuit Breaker
- 5925-00-660-6369 MPN 3XAM1516MG3-3AMP46V400CPS12Circuit Breaker
- 5925-00-826-8887 MPN AMHK71-179-1MG6Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-197-2585 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
CD2-C2C3-15-240-1 | Eaton Corp |