NSN 5925-01-204-4719
Overload Switch
Single pole type body style, plastic case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number KS-20684L2 for national stock number 5925012044719.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-204-4719.
-
MPN or Model
KS-20684L2
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Body Length
2.500 inches -
Body Width
0.750 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.938 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches -
Switch Contact Arrangement
Single pole, double throw -
Fragility Factor
Moderately rugged -
Boss Height
0.140 inches -
Mounting Surface To Terminal End Distance
2.969 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
2 threaded hole -
Storage Type
General purpose warehouse -
Maximum Continuous Load Current Rating Per Pole
0.2 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Switch Location And Position Designation
External at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
0.175 at 200 pct single location and 5.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
General purpose -
Switch Terminal Type
Turret -
Precious Material And Location
Contact surface silver -
Precious Material
Silver -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 threaded stud
More from these suppliers
- 5945-00-251-7376 MPN D161974-101Electromagnetic Relay
- 5935-00-295-6486 MPN 7808GElectrical Receptacle Connector
- 5905-00-562-9931 MPN BA99382-21Nonprecision Nonwire Wound Variable Resistor
- 5905-00-756-5146 MPN KS16285L2-10000HMSInductive Wire Wound Fixed Resistor
- 5905-00-881-2109 MPN GA53314A1674Film Fixed Resistor
- 5950-01-265-1618 MPN G360578-8Radio Frequency Coil
- 5905-00-111-2187 MPN 315974Nonprecision Wire Wound Variable Resistor
- 5305-00-392-0207 MPN 100144Machine Screw
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-204-4719 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
KS-20684L2 | Lucent Technologies Inc |
KS-20684L2 | Eaton Corp |
KS-20684L2 | American Telephone And Telegraph Co |
KS-20684L2 | Lucent Technologies Inc |