NSN 5925-01-204-6096
Overload Switch
Multipole-single actuator type body style, plastic case material, single pole, double throw switch contact arrangement, pole quantity: 3.
Manufacturer part number ETN275410 for national stock number 5925012046096.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-204-6096.
-
MPN or Model
ETN275410
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
6.6 lb -
Body Style
Multipole-single actuator type -
Body Length
6.500 inches -
Body Width
4.125 inches -
Body Height
3.875 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
3.938 inches -
Center To Center Distance Between Terminals Parallel To Width
1.375 inches -
Unthreaded Mounting Hole Diameter
0.190 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.312 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
3.688 inches -
Boss Height
0.188 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
4 unthreaded hole -
Storage Type
General purpose warehouse -
Maximum Continuous Load Current Rating Per Pole
100.0 amperes ac all locations and 100.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
500.0 ac all locations and 250.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
15000.0 ac all locations and 10000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal-magnetic all locations -
Trip Release Characteristic
Instantaneous all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Auxiliary Switch Function And Quantity
1 alarm -
Switch Location And Position Designation
Internal at pole one -
Inclosure Protection Type For Which Designed
General purpose -
Trip Release Ambient Tempurature Rating
50.0 degrees celsius all locations -
Switch Terminal Type
Wire lead -
Switch Current Rating And Type In Amps
15.0 ac and 15.0 dc -
Switch Voltage Rating And Type In Volts
460.0 ac and 250.0 dc -
Frequency In Hertz
400.0 all locations -
Unpackaged Unit Weight
5.500 pounds -
Terminal Type And Quantity
6 compression
More from these suppliers
- 5985-00-295-7108 MPN 487860REVCPT901Radio Frequency Transmission Line
- 5950-00-810-4226 MPN 53269PCA8Electrical Coil
- 5950-01-068-2564 MPN 401070-500VA450-120VPower Transformer
- 5975-01-188-2783 MPN N18-T1Blank Panel
- 5950-00-518-2808 MPN 177943PC1122SH3Electrical Coil
- 5930-01-495-0532 MPN 199023-ASwitch Guard
- 5930-00-862-5582 MPN ETN1086Electrical Switch Yoke
- 5935-01-432-0932 MPN 8-16-12Electrical Plug Connector
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-204-6096 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
ETN275410 | Spd Electrical Systems, Inc |
68E3470 | Eaton Corporation |