NSN 5925-01-208-4754
Overload Switch
Multipole-single actuator type body style, metal case material, at 3 oclock and at 9 oclock nonturn device location, pole quantity: 3.
Manufacturer part number 29-1217615-2 for national stock number 5925012084754.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-208-4754.
-
MPN or Model
29-1217615-2
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-single actuator type -
Bushing Length
Between 0.332 inches and 0.375 inches -
Body Length
1.500 inches -
Body Width
1.875 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
Between 0.844 inches and 0.906 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.595 inches and 0.656 inches -
Nonturn Device Location
At 3 oclock and at 9 oclock -
Nonturn Device Diameter
0.250 inches -
Mounting Surface To Terminal End Distance
1.780 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac first location -
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations -
Circuit Protection Type
Overcurrent third location -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay first location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Internal Trip Release Configuration
Series trip third location -
Thread Size
0.375 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 at 200 pct and 9.000 at 200 pct third location -
Inclosure Protection Type For Which Designed
Hermetically sealed -
Frequency In Hertz
60.0 all locations -
Thread Series Designator
Unef -
Terminal Type And Quantity
6 wire hook and 2 quick disconnect, male
More from these suppliers
- 5985-00-137-4328 MPN 20-807247-1Variable Attenuator
- 5950-00-577-1178 MPN S5661Saturable Reactor
- 5925-00-161-9167 MPN UPL-1-1-62-153Circuit Breaker
- 5925-00-721-3206 MPN AP3-301-32Circuit Breaker
- 5925-00-862-6719 MPN APL111-30-1Circuit Breaker
- 5925-00-948-9112 MPN 510C232Circuit Breaker
- 5925-01-017-0133 MPN UPG1-1-6-2-752-0Circuit Breaker
- 5925-01-023-1410 MPN AP1-1-6-0-103Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-208-4754 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
29-1217615-2 | General Dynamics Advanced |
AP141-5445-1 | Sensata Technologies Maryland, Inc |
Stock Check
![](/public/images/partscage_shelf3.png)