NSN 5925-01-211-3412
Overload Switch
Multipole-single actuator type body style, metal case material, at 3 oclock and at 9 oclock nonturn device location, fragility factor: moderately rugged.
Manufacturer part number AP-112-1-62-103 for national stock number 5925012113412.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-211-3412.
-
MPN or Model
AP-112-1-62-103
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.4 lb -
Body Style
Multipole-single actuator type -
Bushing Length
0.380 inches -
Body Length
1.875 inches -
Body Width
1.500 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
0.625 inches -
Center To Center Distance Between Terminals Parallel To Width
0.875 inches -
Nonturn Device Location
At 3 oclock and at 9 oclock -
Nonturn Device Radius
0.625 inches -
Nonturn Device Length
0.130 inches -
Nonturn Device Diameter
0.140 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
1.780 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.375 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
5.000 at 125 pct and 40.000 at 125 pct all locations -
Inclosure Protection Type For Which Designed
Hermetically sealed -
Frequency In Hertz
50.0 or 60.0 all locations -
Thread Series Designator
Unef -
Terminal Type And Quantity
4 wire hook
More from these suppliers
- 5945-00-729-2622 MPN 300-SPEC.219Electronic Chopper
- 5945-00-946-4099 MPN 010-113-0116-00Electronic Chopper
- 5925-00-308-7181 MPN APL1-61-501-MCircuit Breaker
- 5925-00-356-7455 MPN APL1R-778-24Circuit Breaker
- 5925-00-453-5892 MPN 2638051-150Circuit Breaker
- 5925-01-116-7411 MPN UPL1-2288-3Circuit Breaker
- 5925-01-149-6966 MPN UPGN-66-7242-1Circuit Breaker
- 5925-01-173-2840 MPN 205-11-1REC2-62F-3-752-AMOCircuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-211-3412 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AP-112-1-62-103 | Vdo Control Systems Inc |
AP-112-1-62-103 | Sensata Technologies Maryland, Inc |