NSN 5925-01-213-4197
Overload Switch
Protection barriers between poles.
Manufacturer part number UPL112-20918-1 for national stock number 5925012134197.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-213-4197.
-
MPN or Model
UPL112-20918-1
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.1 lb -
Body Style
Multipole-multiple actuator type -
Body Length
Between 2.480 inches and 2.500 inches -
Body Width
2.265 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 2.925 inches and 2.955 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.735 inches and 0.765 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.050 inches and 2.070 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.735 inches and 0.765 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.135 inches and 0.165 inches -
Mounting Surface To Terminal End Distance
2.000 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
6 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
300.0 amperes ac and 300.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
350.0 ac and 350.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac and 1000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Instantaneous all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Inclosure Protection Type For Which Designed
Corrosion resistant and moisture resistant and shock resistant and vibration resistant -
Frequency In Hertz
400.0 all locations -
Unpackaged Unit Weight
11.100 ounces -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5930-01-556-7138 MPN C54HCC160A-140BThermostatic Switch
- 5925-00-064-1155 MPN 501I301Circuit Breaker
- 5925-00-262-5859 MPN APL111-1-43-303Circuit Breaker
- 5925-01-024-4153 MPN AP1-1-5-2-702Circuit Breaker
- 5925-01-055-1198 MPN 203-2-1-61F-103-4-1-1Circuit Breaker
- 5925-01-069-1069 MPN AP411-1R4419-1Circuit Breaker
- 5925-01-069-2995 MPN APL112-3510-1Circuit Breaker
- 5925-01-107-0841 MPN AP-12-1R-5691-1Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-213-4197 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
UPL112-20918-1 | Sensata Technologies Maryland, Inc |