NSN 5925-01-219-5237
Overload Switch
Multipole-multiple actuator type body style, plastic case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number M55629/4-064 for national stock number 5925012195237.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-219-5237.
-
MPN or Model
M55629/4-064
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-multiple actuator type -
Body Length
2.510 inches -
Body Width
Between 1.437 inches and 1.563 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.660 inches and 1.960 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.719 inches and 0.781 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.046 inches and 2.078 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.719 inches and 0.781 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.109 inches and 0.171 inches -
Mounting Surface To Terminal End Distance
2.800 inches -
Pole Quantity
2 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
4 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
8.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
2 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One and two linked -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
0.600 at 200 pct all locations and 8.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Shock resistant and vibration resistant -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
10.0 ac and 2.0 dc -
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc -
Test Data Document
81349-mil-c-55629 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.). -
Thread Series Designator
Unc -
Terminal Type And Quantity
4 threaded stud -
Specification Data
81349-mil-c-55629/4 government specification
More from these suppliers
- 5905-00-001-5676 MPN RV4SAYSB202ANonprecision Nonwire Wound Variable Resistor
- 5905-00-001-8623 MPN RBR53L54900BRNoninductive Wire Wound Fixed Resistor
- 5905-00-004-7646 MPN RBR71L86600BMNoninductive Wire Wound Fixed Resistor
- 5905-00-006-7018 MPN MILR39007-9Inductive Wire Wound Fixed Resistor
- 5935-00-009-6389 MPN MILC83723-75Electrical Plug Connector
- 5905-00-009-6532 MPN MILR55182-6Film Fixed Resistor
- 5905-00-009-6705 MPN RNR60C1372FSFilm Fixed Resistor
- 5905-00-011-4582 MPN RJ11CL202Nonprecision Nonwire Wound Variable Resistor
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-219-5237 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
M55629/4-064 | Military Specifications |
MIL-C-55629/4 | Military Specifications |