NSN 5925-01-222-2243
Overload Switch
Single pole type body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number 1163-100-125VDC-2 for national stock number 5925012222243.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-222-2243.
-
MPN or Model
1163-100-125VDC-2
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Body Length
Between 5.240 inches and 5.260 inches -
Body Width
Between 1.490 inches and 1.510 inches -
Body Height
Between 2.772 inches and 2.792 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 4.349 inches and 4.369 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 3.052 inches and 3.072 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.490 inches and 0.510 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.209 inches and 0.229 inches -
Pole Quantity
1 -
Arc Quenching Method
Air -
Mounting Facility Type And Quantity
4 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
100.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
240.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic-hydraulic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.190 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
6.000 at 200 pct and 20.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
General purpose -
Thread Series Designator
Unf -
Terminal Type And Quantity
2 screw
More from these suppliers
- 5925-00-058-3004 MPN XAM03MG320Circuit Breaker
- 5925-00-153-4518 MPN PAM1614-10Circuit Breaker
- 5925-00-248-5734 MPN HB2Z2-109Circuit Breaker
- 5925-00-479-3811 MPN CD3-A2A3A3-AB-2-480-3Circuit Breaker
- 5925-00-572-6118 MPN 3XAM1516MG3-70-2Circuit Breaker
- 5925-00-660-3893 MPN 53-119MG3-2-5-416VAC400-3Circuit Breaker
- 5925-00-830-8148 MPN 74-101-7Circuit Breaker
- 5925-00-875-0863 MPN 53-194 MG3-1Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-222-2243 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
1163-100-125VDC-2 | Eaton Corp |
1163-100-125VDC-2 | Eaton Corp |